ModbusInfoBuildWriteMaskModbusCommand 方法 (ModbusAddress, UInt16, UInt16) |
构建Modbus写入掩码数据的核心报文,需要指定地址,长度,站号,是否起始地址0,默认的功能码
To construct the core message of Modbus writing mask data, you need to specify the address, length,
station number, whether the starting address is 0, and the default function code
命名空间:
HslCommunication.ModBus
程序集:
HslCommunication (在 HslCommunication.dll 中) 版本:12.1.2.0 (12.1.2.0)
语法 public static OperateResult<byte[]> BuildWriteMaskModbusCommand(
ModbusAddress mAddress,
ushort andMask,
ushort orMask
)
Public Shared Function BuildWriteMaskModbusCommand (
mAddress As ModbusAddress,
andMask As UShort,
orMask As UShort
) As OperateResult(Of Byte())
public:
static OperateResult<array<unsigned char>^>^ BuildWriteMaskModbusCommand(
ModbusAddress^ mAddress,
unsigned short andMask,
unsigned short orMask
)
static member BuildWriteMaskModbusCommand :
mAddress : ModbusAddress *
andMask : uint16 *
orMask : uint16 -> OperateResult<byte[]>
参数
- mAddress
- 类型:HslCommunication.Core.AddressModbusAddress
Modbus的富文本地址 - andMask
- 类型:SystemUInt16
等待进行与操作的掩码 - orMask
- 类型:SystemUInt16
等待进行或操作的掩码
返回值
类型:
OperateResultByte包含最终命令的结果对象
参见