| FujiSPBHelperReadBoolAsync 方法  | 
 
            批量读取PLC的Bool数据,以位为单位,支持读取X,Y,L,M,D,TN,CN,TC,CC,R,W,例如 M100, 如果是寄存器地址,可以使用D10.12来访问第10个字的12位,地址可以携带站号信息,例如:s=2;M100
            Read PLC's Bool data in batches, in units of bits, support reading X, Y, L, M, D, TN, CN, TC, CC, R, W, such as M100, if it is a register address, 
            you can use D10. 12 to access the 12 bits of the 10th word, the address can carry station number information, for example: s=2;M100
            
 
        命名空间: 
     HslCommunication.Profinet.Fuji
        程序集:
     HslCommunication (在 HslCommunication.dll 中) 版本:12.5.1.0 (12.5.1.0)
 语法
语法public static Task<OperateResult<bool[]>> ReadBoolAsync(
	IReadWriteDevice device,
	byte station,
	string address,
	ushort length
)
Public Shared Function ReadBoolAsync ( 
	device As IReadWriteDevice,
	station As Byte,
	address As String,
	length As UShort
) As Task(Of OperateResult(Of Boolean()))
public:
static Task<OperateResult<array<bool>^>^>^ ReadBoolAsync(
	IReadWriteDevice^ device, 
	unsigned char station, 
	String^ address, 
	unsigned short length
)
static member ReadBoolAsync : 
        device : IReadWriteDevice * 
        station : byte * 
        address : string * 
        length : uint16 -> Task<OperateResult<bool[]>> 
参数
- device
- 类型:HslCommunication.CoreIReadWriteDevice
 PLC设备通信对象
- station
- 类型:SystemByte
 当前的站号信息
- address
- 类型:SystemString
 地址信息,举例:M100, D10.12
- length
- 类型:SystemUInt16
 读取的bool长度信息
返回值
类型:
TaskOperateResultBooleanBool[]的结果对象
 参见
参见