[商业授权] 读取PLC的标签信息,需要传入标签的名称,读取的字长度,标签举例:A; label[1]; bbb[10,10,10]
[Authorization] To read the label information of the PLC, you need to pass in the name of the label, 
            the length of the word read, and an example of the label: A; label [1]; bbb [10,10,10]
            
 
        命名空间: 
     HslCommunication.Profinet.Melsec.Helper
        程序集:
     HslCommunication (在 HslCommunication.dll 中) 版本:12.5.1.0 (12.5.1.0)
 语法
语法public static OperateResult<byte[]> ReadTags(
	IReadWriteMc mc,
	string[] tags,
	ushort[] length
)
Public Shared Function ReadTags ( 
	mc As IReadWriteMc,
	tags As String(),
	length As UShort()
) As OperateResult(Of Byte())
public:
static OperateResult<array<unsigned char>^>^ ReadTags(
	IReadWriteMc^ mc, 
	array<String^>^ tags, 
	array<unsigned short>^ length
)
static member ReadTags : 
        mc : IReadWriteMc * 
        tags : string[] * 
        length : uint16[] -> OperateResult<byte[]> 
参数
- mc
- 类型:HslCommunication.Profinet.Melsec.HelperIReadWriteMc
 MC协议通信对象
- tags
- 类型:SystemString
 标签名
- length
- 类型:SystemUInt16
 读取长度
返回值
类型:
OperateResultByte是否成功
 备注
备注
             不可以访问局部标签。
             不可以访问通过GX Works2设置的全局标签。
             为了访问全局标签,需要通过GX Works3的全局标签设置编辑器将“来自于外部设备的访问”的设置项目置为有效。(默认为无效。)
             以ASCII代码进行数据通信时,由于需要从UTF-16将标签名转换为ASCII代码,因此报文容量将增加
            
 参见
参见