OmronCipNet 属性 |
OmronCipNet 类型公开以下成员。
名称 | 说明 | |
---|---|---|
ByteTransform |
当前的数据变换机制,当你需要从字节数据转换类型数据的时候需要。 (继承自 DeviceCommunication。)The current data transformation mechanism is required when you need to convert type data from byte data. | |
CipCommand |
获取或设置整个交互指令的控制码,默认为0x6F,通常不需要修改 (继承自 AllenBradleyNet。)Gets or sets the control code of the entire interactive instruction. The default is 0x6F, and usually does not need to be modified. | |
CommunicationPipe | (继承自 BinaryCommunication。) | |
ConnectionId |
当前连接的唯一ID号,默认为长度20的guid码加随机数组成,方便列表管理,也可以自己指定 (继承自 BinaryCommunication。)The unique ID number of the current connection. The default is a 20-digit guid code plus a random number. | |
ConnectTimeOut |
获取或设置接收服务器反馈的时间,如果为负数,则不接收反馈 (继承自 DeviceTcpNet。)Gets or sets the time to receive server feedback, and if it is a negative number, does not receive feedback | |
IpAddress |
获取或是设置远程服务器的IP地址,如果是本机测试,那么需要设置为127.0.0.1 (继承自 DeviceTcpNet。)Get or set the IP address of the remote server. If it is a local test, then it needs to be set to 127.0.0.1 | |
LocalBinding |
获取或设置绑定的本地的IP地址和端口号信息,如果端口设置为0,代表任何可用的端口 (继承自 DeviceTcpNet。)Get or set the bound local IP address and port number information, if the port is set to 0, it means any available port | |
LogNet |
组件的日志工具,支持日志记录,只要实例化后,当前网络的基本信息,就以DEBUG等级进行输出 (继承自 BinaryCommunication。)The component's logging tool supports logging. As long as the instantiation of the basic network information, the output will be output at DEBUG | |
MessageRouter |
获取或设置当前的通信的消息路由信息,可以实现一些复杂情况的通信,数据包含背板号,路由参数,slot,例如:1.15.2.18.1.1 (继承自 AllenBradleyNet。)Get or set the message routing information of the current communication, which can realize some complicated communication. The data includes the backplane number, routing parameters, and slot, for example: 1.15.2.18.1.1 | |
Port |
获取或设置服务器的端口号,具体的值需要取决于对方的配置 (继承自 DeviceTcpNet。)Gets or sets the port number of the server. The specific value depends on the configuration of the other party. | |
PortSlot |
port and slot information
(继承自 AllenBradleyNet。) | |
ReceiveTimeOut |
获取或设置接收服务器反馈的时间,如果为负数,则不接收反馈 (继承自 BinaryCommunication。)Gets or sets the time to receive server feedback, and if it is a negative number, does not receive feedback | |
SendBeforeHex |
获取或设置在发送通信报文前追加发送的字节信息,HEX格式,通常用于lora组网时,需要携带 00 00 00 02 四个字节的站地址功能。 (继承自 BinaryCommunication。)Obtain or set the byte information sent before sending communication packets, HEX format, usually used for LORA networking, you need to carry 00 00 00 02 four-byte station address function. | |
SessionHandle |
The current session handle, which is determined by the PLC when communicating with the PLC handshake
(继承自 AllenBradleyNet。) | |
SleepTime |
获取或设置在正式接收对方返回数据前的时候,需要休息的时间,当设置为0的时候,不需要休息。 (继承自 BinaryCommunication。)Get or set the time required to rest before officially receiving the data from the other party. When it is set to 0, no rest is required. | |
Slot |
Gets or sets the slot number information for the current plc, which should be set before connections
(继承自 AllenBradleyNet。) | |
SocketKeepAliveTime |
获取或设置客户端的Socket的心跳时间信息,这个是Socket底层自动实现的心跳包,不基于协议层实现。默认小于0,不开启心跳检测,如果需要开启,设置 60_000 比较合适,单位毫秒 (继承自 DeviceTcpNet。)Get or set the heartbeat time information of the Socket of the client. This is the heartbeat packet automatically implemented by the bottom layer of the Socket, not based on the protocol layer. The default value is less than 0, and heartbeat detection is not enabled. If you need to enable it, it is more appropriate to set 60_000, in milliseconds. | |
WordLength |
一个字单位的数据表示的地址长度,西门子为2,三菱,欧姆龙,modbusTcp就为1,AB PLC无效 (继承自 DeviceCommunication。)The address length represented by one word of data, Siemens is 2, Mitsubishi, Omron, modbusTcp is 1, AB PLC is invalid |